News
人材検索について
ハイパフォーマンススポーツに係る研究者やサポートスタッフ等の人材情報の検索ができます。HPSCに現在勤務する職員(HPSCスタッフ)、HPSCの勤務経験者(HPSC OB/OG)、HPSCの各種事業における協力者(HPSC事業協力者)のカテゴリーに分けております。人材データベースへのご登録はHPSCからご依頼させて頂いた方のみとしております。
最終更新日:2024/10/29
髙橋 英幸
タカハシ ヒデユキ
(Hideyuki TAKAHASHI)
論文
- タイトル
- タイトル(英)
- Comparison of bioelectrical impedance indices for skeletal muscle mass and intracellular water measurements of physically active young men and athletes.
- 参照URL
- https://researchmap.jp/takahashi-hideyuki/published_papers/42932599
- 著者
- 著者(英)
- Hiroyuki Sagayama,Emi Kondo,Yoko Tanabe,Akiko Uchizawa,William J Evans,Mahalakshmi Shankaran,Edna Nyangau,Marc Hellerstein,Keisuke Shiose,Tsukasa Yoshida,Jun Yasukata,Yasuki Higaki,Takahiro Ohnishi,Hideyuki Takahashi,Yosuke Yamada
- 担当区分
- 概要
- 概要(英)
- BACKGROUND: Bioelectrical impedance analysis (BIA) is a minimally invasive, safe, easy, and quick technology used to determine body composition. OBJECTIVE: We compared the relationship among impedance indices obtained using single-frequency BIA, multi-frequency BIA, bioelectrical impedance spectroscopy (BIS), and skeletal muscle mass (SMM) of physically active young men and athletes using the creatine (methyl-d3) dilution method. We also compared the SMM and intracellular water (ICW) of athletes and active young men measured using a reference stable isotope dilution and BIS method, respectively. METHODS: We analyzed data of 28 men (mean age, 20 ± 2 years) who exercised regularly. Single-frequency BIA at 5 kHz and 50 kHz (R5 and R50), multi-frequency BIA (R250-5), and BIS (RICW) methods of determining the SMM were compared. The deuterium and bromide dilution methods of obtaining the total body water, ICW, and extracellular water measurements were also used, and the results were compared to those acquired using bioimpedance methods. RESULTS: The correlation coefficients between SMM and L2/R5, L2/R50, L2/R250-5, and L2/RICW were 0.738, 0.762, 0.790, and 0.790, respectively (p < 0.01). The correlation coefficients between ICW and L2/R5, L2/R50, L2/R250-5, and L2/RICW were 0.660, 0.687, 0.758, and 0.730, respectively (p < 0.001). However, the correlation coefficients of L2/R50, L2/R250-5, and L2/RICW for SMM and ICW were not significantly different. CONCLUSIONS: Our findings suggest that single-frequency BIA at L2/R50, multi-frequency BIA, and BIS are valid for assessing the SMM of athletes and active young men. Additionally, we confirmed that the SMM and ICW were correlated with single-frequency BIA, multi-frequency BIA, and BIS. Bioimpedance technologies may be dependable and practical means for assessing SMM and hydration compartment status of active young adult males, however, cross-validation is needed.
- 出版者・発行元
- 出版者・発行元(英)
- 誌名
- 誌名(英)
- The Journal of nutrition
- 巻
- 号
- 開始ページ
- 終了ページ
- 出版年月
- 2023年7月24日
- 査読の有無
- 査読有り
- 招待の有無
- 掲載種別
- 研究論文(学術雑誌)
- ISSN
- DOI URL
- https://doi.org/10.1016/j.tjnut.2023.07.010
- 共同研究・競争的資金等の研究課題