News


人材検索について

ハイパフォーマンススポーツに係る研究者やサポートスタッフ等の人材情報の検索ができます。HPSCに現在勤務する職員(HPSCスタッフ)、HPSCの勤務経験者(HPSC OB/OG)、HPSCの各種事業における協力者(HPSC事業協力者)のカテゴリーに分けております。人材データベースへのご登録はHPSCからご依頼させて頂いた方のみとしております。

最終更新日:2025/04/03

秋山 圭

(Kei Akiyama)
論文
タイトル
The validity and reliability of a smartphone app for measuring break-point angle during Nordic hamstring exercise
タイトル(英)
The validity and reliability of a smartphone app for measuring break-point angle during Nordic hamstring exercise
参照URL
https://researchmap.jp/kakikaki/published_papers/42963898
著者
Toshiaki Soga,Shota Yamaguchi,Takayuki Inami,Hiromi Saito,Nadaka Hakariya,Naoto Nakaichi,Sho Shinohara,Kei Akiyama,Norikazu Hirose
著者(英)
Toshiaki Soga,Shota Yamaguchi,Takayuki Inami,Hiromi Saito,Nadaka Hakariya,Naoto Nakaichi,Sho Shinohara,Kei Akiyama,Norikazu Hirose
担当区分
概要
概要(英)
Background A recently developed smartphone application (Nordic Angle) allows the automatic calculation of the break-point angle (BPA) during Nordic hamstring exercise (NHE) without transferring the collected data to a computer. The BPA is the point at which the hamstrings are unable to withstand force. However, the validity of the BPA values obtained by this method has not been examined. Hypothesis/Purpose This study aimed to evaluate the validity and reliability of the Nordic Angle by comparing the BPA values of the Nordic Angle with those of two-dimensional motion analysis software that can calculate the angles and angular velocities of various joints. Study Design Cohort assessing Validity and Reliability Methods The validity of the Nordic Angle BPA data was verified by Spearman’s correlation test for consistency with the movement analysis data, and the magnitude of the correlation was indicated by rs. The agreement between these measurements was examined using the Bland-Altman analysis. The reliability of the Nordic Angle and motion analysis was examined using the intraclass correlation coefficient (ICC) (1,k) based on data from repeated trials within a day. Results Although the spearman correlation between the Nordic angle and the angle determined using motion analysis did not reach statistical significance (p = 0.052), a very large correlation was present (rs = 0.75). The difference between the mean values of the Nordic Angle and motion analysis was 0.4 ± 2.1°, and the limits of agreement ranged from -3.9° to 4.6°. In two BPA measurements, the Nordic Angle showed perfect reliability (ICC = 1.00, p < 0.001), while motion analysis showed nearly perfect reliability (ICC = 0.97, p < 0.001). Conclusion The Nordic Angle, which has both validity and reliability, may be appropriate for field measurement because it allows immediate feedback of BPA and the measurement of many athletes. Level of evidence 3b
出版者・発行元
出版者・発行元(英)
International Journal of Sports Physical Therapy
誌名
誌名(英)
International Journal of Sports Physical Therapy
18
4
開始ページ
終了ページ
出版年月
2023年8月
査読の有無
査読有り
招待の有無
掲載種別
研究論文(学術雑誌)
ISSN
DOI URL
https://doi.org/10.26603/001c.83936
共同研究・競争的資金等の研究課題