News
人材検索について
ハイパフォーマンススポーツに係る研究者やサポートスタッフ等の人材情報の検索ができます。HPSCに現在勤務する職員(HPSCスタッフ)、HPSCの勤務経験者(HPSC OB/OG)、HPSCの各種事業における協力者(HPSC事業協力者)のカテゴリーに分けております。人材データベースへのご登録はHPSCからご依頼させて頂いた方のみとしております。
最終更新日:2025/06/02
小島 千尋
コジマ チヒロ
(Chihiro Kojima)
論文
- タイトル
- タイトル(英)
- Conversion Reaction of Stable-Isotope Oxygen Labeling of Carboxylic Acids for Accurate Screening LC-MS/MS Assay: Application of Behavioral Changes of Short-Chain Fatty Acids in Sports Athletes under Exercise Loading.
- 参照URL
- https://researchmap.jp/c-kojima1027/published_papers/50299759
- 著者
- 著者(英)
- Aoi Ichikawa,Takahiro Takayama,Chihiro Kojima,Shumpei Fujie,Motoyuki Iemitsu,Koichi Inoue
- 担当区分
- 概要
- 概要(英)
- Short-chain fatty acids (SCFAs) have attracted considerable interest as potential biomarkers, therapeutic targets, and nutritional factors in athletic training. SCFAs are typically produced by the intestinal microbiome and exhibit various structural forms, including linear- and branched-chain types. In particular, branched-chain SCFAs have been associated with muscle metabolism during exercise loading. Consequently, accurate and efficient analytical methods are essential for identifying these biomarkers. Liquid chromatography-tandem mass spectrometry is a suitable and accurate technique for SCFA analysis; however, stable isotope calibrations are required for all analytes. Because of technological limitations, the available species are restricted to certain types of SCFAs. To address this issue, this study performed a simple conversion reaction involving the incorporation of 18O into the carboxyl group. Specifically, oxygen atoms in the carboxyl groups were substituted with 18O sourced from commercially available H218O. An SCFA mixture standard solution was successfully labeled under optimized conditions, and the SIL purity and amount were sufficient for isotope dilution (95.2-96.9%, 250 assays using 10 μL of H218O). Moreover, no reversion to 16O was observed during storage or analysis. Analytical validation was performed in human serum using the substituted isotopic standard mixture, achieving good accuracy (90-110%) and precision (<10% relative standard deviation) across three concentration levels. Finally, changes in SCFA patterns were examined in athletes during exercise loading.
- 出版者・発行元
- 出版者・発行元(英)
- 誌名
- 誌名(英)
- Analytical chemistry
- 巻
- 97
- 号
- 14
- 開始ページ
- 7765
- 終了ページ
- 7771
- 出版年月
- 2025年4月15日
- 査読の有無
- 査読有り
- 招待の有無
- 掲載種別
- 研究論文(学術雑誌)
- ISSN
- DOI URL
- https://doi.org/10.1021/acs.analchem.4c05872
- 共同研究・競争的資金等の研究課題